EPS-H104NV1 -- 12" 4 Outlet Hardwired Metal Power Strip
EPS-H104NV1 -- 12" 4 Outlet Hardwired Metal Power Strip
Larger Image
Product Name:EPS-H104NV1 -- 12" 4 Outlet Hardwired Metal Power Strip
Our Price:$16.99
Availability:In Stock
Product Number:EPS-H104NV1
Rating:

 Product Detail

EPS-H104NV1
EPS-H104NV1 -- 12" Hardwired Power Strip with 4 Outlets

This hard wired type power strip is good for installation in your kitchen, cabinet, on the rack and so on. It is not for normal wall outlets. There is no power cord and plug with this unit.

Features
  • 12" (0.30m) Durable Metal Housing Power Strip
  • 4 Black US Standard Outlets, Vertical Outlet Orientation
  • Hard Wired without Power Cord for Mounting at Your Desired Location
  • 6 Easily Punched off Knockouts on Each Side - on Top, Both Sides, the Bottom Cover and Both Ends
  • ETL Approved and Listed (Conforms to UL5 and CAN/CSA C22.2 No. 62)
  • Easy Installation
  • Wires Readily Striped for Easier Removal and Faster Installation - Higher Efficiency


Specification

Model #:

EPS-H104NV1

Description:

12" 4 Outlet Hardwire Type Metal Power Strip

Power Strip Measurement:

L12" x W1.614" x H1.535" (305 x 41 x 39mm) *

Outlets:

4

Outlet Color:

Black

Outlet Orientation:

Vertical

Receptacle Type

NEMA 5-15R

Outlet Spacing:

1.30/2.28" or 33/58mm (center to center)

Knockout Cord Exit:

6 (Top, Bottom Cover, Both Sides & Both Ends)

Voltage Input/Output:

110-125V 60Hz

Current Input:

15A

Full Load:

1875VA

On/Off Switch:

N/A

Circuit Breaker:

N/A

Surge Protection:

N/A

Indicators:

N/A

Mounting Tabs:

N/A

Mounting Clips:

2 x ¾" (19mm) Spring Clips (Click here)



SAFETY WARNING:

Installation work of this unit must be done by a professional, a licensed electrician or an electric engineer.

Never install this unit during a thunder storm.

Switch off the power before you start installation work.

This unit is for indoor use only.

This unit is not intended for use in or around wet or potentially wet areas including, but not limited to, aquariums, saunas, showers and fountains.

Risk of Electric Shock!



INSTALLATION Guideline:

Before installation, you will need to get a 3/8" wire clamp connector (also known as Romex Connector) and 3 wire connectors (also referred to as terminal connectors. Decide your wire gauge, and ask store attendant for assistance what color of connectors you should get) from your local hardware or electric supply or home improvement stores.


Minimum tool required:
A fine to medium fine philips screw driver, and a pair of scissors, and a pair of mid size slip joint pliers
  1. Turn off electricity in the house
  2. Decide where to place this unit
  3. Choose the right side for cord exit and mark on the knockout coin
  4. Gently punch off the knockout coin marked earlier with the back of a screw driver or other tool handy
  5. Unscrew the cover off the back of the power strip with a philips screw driver
  6. Take out the white plastic insulation sheet, then use the pair of scissors to cut a hole (about ¾" in diameter, or big enough for the wires to go through) on this white plastic insulation sheet WHERE the wires will run through. (If you decide to use the bottom knockout on the back cover for wire connection, the hole should be in the middle of the sheet. Or, on the side.)
  7. Put the 3/8" wire clamp connector you already have in place. The big ring screw inside the wall and the two screws outside the wall. Secure the installation of the clamp connector by tightening the big ring screw from inside the wall with the pair of slip joint pliers
  8. Run the wires through the wire clamp connector, from the outside into the power strip
  9. Please remember to run through the wires through the white plastic insulation sheet
  10. Match the color of the wires and secure the wire connection with proper wire connectors (different wire gauge use different colored wire connectors)
  11. Tighten the two screws properly on the wire clamp connector
  12. Put back the insulation sheet back in place
  13. Screw the back cover on
  14. Mount the power strip where you want it to be:
    A) For power strips with mounting tabs on both ends: screw down the unit on the floor, wall or in your cabinet or on your rack, where you want it to be
    B) For power strips without mounting tabs, but to be mounted with clips, place the unit where you want it to be first, draw a line so that you know where to install the clips. Place clips about 6" away from each end, and screw the clips down with screws provided. Then, snap the power strip in
  15. Turn electricity back on, you are ready to go


Note
:

* For installation purpose: The length of the power strip does not include the mounting tabs (approx. 0.624"/15.8mm on both ends, if available, please check the above spec chart); the width does not include the size of screws (min. 0.064"/1.6mm on each side); the height does not include the receptacles (about 0.208"/5.3mm above the surface of the strip).